详细信息
 重量:   ET-GC930 ((kg))  功率:   美国博科 ((w))

特色功能:ET-GC910气相色谱仪可实现多功能、高精度的分析。在较差的环境下,也能得到实验室水平的结果。通过PeakSimple软件,   技术参数: 1.柱箱尺寸:7.5 2.温度范围:室温——450℃ 3.控温精度:±0.1℃(400℃以下) 4.重量:40——70磅(由选择的配置而定) 5.电源:110VAC/60HZ或220VAC/50HZ,功耗750W 详细介绍 GC910气相色谱仪可实现多功能、高精度的分析。在较差的环境下,也能得到实验室水平的结果。通过PeakSimple软件,GC910提供全部的控制应用参数。 1.可配双柱箱,并可实现独立温控 2.柱箱温度可编程 3.内置阀可满足精度分析的要求 4.在整个温度范围内利用电子压力控制保持平面基线 5.可在严格的实验室或场地条件下进行研究品质分析   检测器:   1) TCD (Thermal Conductivity Detector) A “universal” detector able to measure almost ALL molecules; inorganic andpermanent gases as well as organic vapors. Operates below 275oC, and gives a typical DL of ~250PPM, with linearity to~100% for most species. A good nondestructive detector for general Organic and Analytical testing, it is also used forCombustion Gas and Stack Gas testing, Atmospheric monitoring, and bulk measurements. Helium is the recommended carrier.2) FID (Flame Ionization Detector) Commonly used for Organic analyses, it is specific for Hydrocarbon species with aworking range from ~10PPM to 10% for C1-C10 compounds. It has a high temperature range, over 400oC, and can beinterfaced with add-on detectors for selective-species measurements. Solvent and material characterization, environmentalsamples, TPH and petroleum analyses are primary applications. Air & Hydrogen are support gases, using Helium for a carriergas.3) DELCD (Dry Electro-Lytic Conductivity Detector) This detector, with FID, is ideal for environmental applications whereHalogenated Hydrocarbons and Pesticides can be easily differentiated from Solvent matrix backgrounds. Cleaner and morelinear response of DELCD compared to ECD still gives sensitivities in the 10PPB range; and meets most EPA specifications forthe 600- and 8000-series methods. Works best using Helium for a carrier, with Air & Hydrogen as supplemental gases.4) HID (Helium Ionization Detector) Provides “universal” detection; and is non-destructive, similar to TCD; for gaseousspecies with an Ionization Potential below that of Helium. Less expensive than similar detectors; it provides DLs of ~1-10PPMfor most gases. Suited for special tests; such as Transformer Oil Gases, Road Bed Emissions and other non-Organic vapormeasurement. High-quality Helium is required as Carrier.5) NPD (Nitrogen Phosphorus Detector) Designed for Agricultural and Drug testing, this modified Thermionic Bead Detectorresponds to Nitrogen-bearing compounds to concentrations of ~100PPB or lower; with Phosphorus-containing materialsdetectable at ~500PPB. As part of an FID assembly, it needs the Air-Hydrogen jet to burn the eluting “peak” with a Heliumcarrier.6) ECD (Electron Capture Detector) Originally designed for single PPB level detection of Chlorinated organic compounds, itrequires a special carrier gas of Argon-Methane and low-bleed columns for optimal results Still the most sensitive detectoravailable for the environmental monitoring of Halocarbons and Pesticides, with 1-5PPB detection limits. Usually run independentof other detectors.7) PID (Photo-Ionization Detector) A high-intensity “UV” source, the 10.6eV Krypton Lamp generates powerful energy to“excite” UNSATURATED organic; such as Aromatics, Olefins, Ketones and Esters. The low 10-50PPB DLs for the Aromaticcompounds make it ideal for environmental testing for BTEX, PAH and PNA species. Non-destructive measurements make itideal for use with an FID/combo detector.8) FPD (Flame Photometric Detector) Employs either a single- or double-phototube detector that “sees” the light from burningSulfur or / and Phosphorus compounds. Crucial for Stack and Combustion Gas testing,Natural Gas, refined Hydrocarbons andeven Pesticide materials. Superior detection limits in the 1-10PPB range are achieved with advance electronics and proprietaryoptical designs. Uses a rich Hydrogen flame, often used in conjunction with FID and with a Helium carrier gas.9) CCD (Catalytic Combustion Detector) A unique and economical alternative to the FID for the detection of hydrocarboncompounds has a typical detection limit of about 500 ppm when run with a helium carrier. The CCD can also run at lowertemperatures (<200°) when run on air to make a truly self contained GC.Note: Many of these detectors can be, and often should be combined to maximize the usefullnes of the Buck GC. Packagessuch as FID-DELCD, TCD-FID, PID-FID- DELCD, NPD-DELCD, FID-FPD. Call for specific application help on yourapplication.   进样器: Several injection options are available for the Buck 910/310.Injector types and configurations are selected by the user depending on theparticular measurement application, detection limit required and regulatoryspecifications. All injectors require factory installation.On-Column InjectorThe On-Column injector is supplied standard on all 910/310 GCs. This mode of injectionintroduces the sample directly into the bore of the column, avoiding the possibility of boilingpoint discrimination or other uncertainties. A heated injector upgrade is available.Heated Split/SplitlessThe Heated Split/Splitless injector permits the use of narrow-bore capillary columns whenneeded. The injector temperature is adjustable from ambient to 300oC and the split flow isadjustable by means of a precision needle valve. This feature can be turned on/off by usinga timed event from the PeakSimple software.10 Port Gas Sampling Valve & Heated Valve OvenThe 10 Port Gas Sampling valve can be plumbed in many ways to perform a variety of analytical tasks, providing additionalflexibility to the 910. Because the valve oven is immediately next to the column oven, tubing runs are short with no cold spots,which results in sharper peaks. Buck offers many plumbing configurations for optimized gas analyses. The heated valve ovenconsists of an insulated aluminum box mounted immediately next to the column oven. This means very little tubing is needed forconnections which results in sharper peaks. The valve oven can accomodate 2 electrically operated plus one manually operatedvalve and can be thermostatted from ambient to 175oC. A heated oven is highly recommended for gas sampling valve mountingand is required for several other options42 Vial Liquid And 20 Vial Internal AutoSamplerThe autosampler uses readily available 2ml vials with crimp or screw tops. Theautosampler flushes its syringe with the sample itself, so each vial must be filledwith at least 1ml of sample. The PeakSimple data system tells the autosamplerto flush the syringe, inject the sample and then advance the tray to the next vialposition. The autosampler can be used with the on-column, heated, or split/splitless injectors. The 42 vial external Autosampler requires nitrogen, air orhelium at 60 psi to actuate the moving parts. The internal 20 vial Autosampleris electronically actuated and is run from peaksimple sample queue. Theinjection volume is adjustable from 0-3 μl.Heated Static Headspace InjectorThe Heated Static Headspace Injector is useful for the analysis of volatiles,especially where the sample matrix is dirty. A standard 40ml VOA vial isinserted into a thermostatted sleeve, where two needles puncture the septumtop of the vial. Purge gas enters through one needle to pressurize the vial and the other needle carries the headspace vapors to theloop of the gas sampling valve or trap.EPA Method 5030/5035 Compliant Purge & TrapThe 5030 as well as the 5035 Compliant Purge & Trap concentrate the volatile organic compounds (VOCs) in a gas, water, or soilsample onto two adsorbent traps from which they are automatically desorbed into the GC column. The 5035 Purge & Trap isequipped with an adjustable temperature thermostatted sleeve that accommodates a standard 40ml VOA vial containing the wateror soil/water sample. The entire sleeve is mechanically agitated during purging to comply with the requirements of EPA Method5035.   PeakSimple-软件: PeakSimple chromatography software combines quicklearning, ease of use and convenient powerful featuresfor GC and HPLC. PeakSimple is included in the priceof every Buck Gas Chromatograph and Data System.PeakSimple’s intuitive graphical functions and featuresare user-friendly, so most operators can produce resultsalmost immediately and without specific training. YetPeakSimple is packed with state-of-the-art features likedraggable retention time windows, seldom found in othersoftware packages costing much more.PeakSimple has the ability to be used with a smallportable notebook or a full-sized computer to controlinstrument functions and process data. This feature ishighly desirable for field applications. There is noadditional hardware or interfaces required.PeakSimple even includes built-in data validation, anextra cost on other data systems. This option allowsyou to replay and load a stored chromatogram, to determine the reproducibility and precision of the entire system.PeakSimple also includes baseline subtraction, chromatogram overlays, DDE links, peak alarms, report generation,multi-level calibrations, autosampler queue, batch reprocessing and many other convenient features. Peaksimpledata stations are available in 1, 4, and 6 channel systemsand now with USB data connection.? Manually Re-integrate ChromatogramsAllows the user to refine the integrationmethod applied to any peak? Click and Drag Retention WindowsRetention windows brackets are visible on-screenand may be dragged and modified.? Print Chromatograms in ColorPrint multiple color chromatograms per page foreasy detector to detector comparisons? Autosampler Queue and BatchProcessingCreate customized autosampler sequences for anyapplication? Zoom in on a Specific Area of DataZoom to a particular channel or zoom to anexpanded view for close examination of small peaks? Temperature ProgrammingProgram one or two GC column ovens fromambient to 450oC with unlimited ramps and holds? Overlay ChromatogramsOverlay the data in any channel onto any otherchannel for retention time comparison ormulti-detector correlation? Baseline SubtractionUseful to compensate for baseline drift due to blankcontamination, column bleed, and temperatureramping? Multi-level Calibration CurvesCalibrate peaks using single or averaged data atup to seven concentration levels? Manual/Automatic External Event ControlPerform timed integration events and controlexternal contact closure relays? EPC and HPLC Gradient ProgrammingProgram carrier gas pressure with unlimited rampsand holds on GC’s and form binary HPLC gradients? Dynamic Data Exchange (DDE)Link PeakSimple results to your DDE compatiblespreadsheet or word processor   色谱选配件: Vacuum Pump InterfaceThis interface will allow control of an external vacuum pump by turning the power on and off on a built-in power outlet.Typically a vacuum pump is used to draw gaseous samples through the traps for ambient air monitoring applications orto load the loop of a gas sampling valve by pulling sample gas from a remote location. Because the vacuum pump can beturned on for a precise length of time, the gas flow through the trap is very reproducible and will vary with pump rate.Packed and Capillary ColumnsBuck can supply and install most types of columns. The metal megabore capillarycolumns are preferred because they are durable, can be coiled to a smaller diameter,yet cost and work the same as fused silica columns, which tend to break. For someapplications (gases, freons, water, etc.) 1/8” packed columns are preferred. However,since every application is unique, consult a column manufacturer(Restek, Supelco,etc.) before selecting a column to purchase with your GC.Methanizer AccessoryThe methanizer accessory is a high efficiency catalyst which is mounted inside theFID and thermostatted to 380oC. The tube is packed with a special nickel catalystpowder where CO and CO2 are converted to methane for detection by FID down to1ppm. This methanize design must be configured with a FID detector.Built-in Air Compressor And Hydrogen GeneratorThe built-in “whisper quiet” air compressor is mounted inside the chassis of the 910 GC where it provides a nearly silentsupply of air for the FID or FID/DELCD detector flame. With the built-in air compressor, no air cylinder is required,simplifying field operations and saving the expense of replacing air cylinders on a regular basis. The hydrogen generatorcan run an FID detector for days on a single filling of water, saving even more money and space.Gas Line Installation KitThe Gas line installation kit includes everything you need to connect a single gas cylinder to the 910 GC.Each kit contains:Cylinder pressure regulator (0-100 PSI output)50’ length of 1/8” copper tubingStainless steel gas line filterHandy tubing cutterExtra Swagelok nuts and ferrulesNote- Each type of gas cylinder has a different type of CGA connection to theregulator. Air is typically CGA 590 or 346, Helium and Nitrogen are CGA 580, whileHydrogen and Argon-Methane are CGA 350. Please specify CGA type.GC Maintenance KitThe GC maintenance kit includes most parts which could fail and is designedespecially for our export customers who may have difficulty returning the GC to thefactory for service.Pre-Configured SystemsBuck offers an assortment of popular pre-configured systems for specific applications:Educational GC TCD Multiple Gas GC PCB AnalyzerMultiple Gas GC w/ Sulphur BTEX GC Enviromental GCTO-14 Indoor Air GC Gas-less Educational GC Educational GC FID
其它相关产品
相关搜索推荐
找不到合适信息?

留下您的采购意愿,我们将帮您推荐诚信供应商!
注:此功能仅对企业用户开放,如果您不是企业用户请点击注册.

免责说明
本网所展现的公司信息、产品信息及其他相关信息均由企业自行提供,信息的真实性、准确性和合法性由商铺所属企业完全负责。全球石油化工网对此不承担任何保证责任。
关于我们 | 会员服务 | 电子样本 | 邮件营销 | 网站地图 | 诚聘英才 | 意见反馈
Copyright @ 2012 CIPPE.NET Inc All Rights Reserved 全球石油化工网 版权所有
京ICP证120803号 京ICP备05086866号-8 京公网安备110105018350