导航:全球石油化工网 >> 产品频道 >> 安防、节能、环保 >> 环境检测仪器 >> 在线监测仪
  • 厦门馈恩洁净用品有限公司
  • 化工币: 100
  • 诚信指数:20   诚信等级:诚信等级:二星级
  • 荣誉证书:0 项
  • 联系人:
  • 电话:86 592 5628410   15859227326
  • 邮箱:
  • 公司地址:中国 福建 厦门市湖里区 厦门市翔安区马巷镇后许村路北94号
  • (联系时,请一定说明是从全球石油化工网看到的)
  • 最近供应 | 诚信档案 | 企业介绍
该公司还有1条同类“在线监测仪”供应商机
详细信息
 类型:   电压在线监测仪  功率:   焊接桌面 ((W))
 测量精度:   0-50V  测量范围:   22x61x63(mm)

SpecificationParameter Overvoltage Alarm 3M™ Iron Man™ Monitor 3M™ Iron Man™ Plus MonitorAlarm Threshold Ranges 0...+/-5V; 0...+/-50V 0...+/-5V; 0...+/-50VThreshold Adjustment Potentiometer PotentiometerThreshold Range Range selected by jumper Range selected by jumperOperator GroundingWrist Strap Dual, 3.5 mm plugOperator's resistance alarm YesOperator body voltage alarm YesMatResistance to ground YesAlarmVisual LED LEDAudio Buzzer BuzzerGeneralDimensions 0.85 in. H x 2.4 in. W x 1.63 in. L22 mm H x 61 mm W x 42 mm L0.85 in. H x 2.4 in. W x 2.5 in. L22 mm H x 61 mm W x 63 mm LPower External Adapter External AdapterWhy Overvoltage?The soldering iron provides metal-to-metal contact with the most sensitive components on the circuit board. A malfunctioningsoldering iron may expose the components to a significant voltage via its tip, including electrostatic discharge (ESD event) and/orelectrical overstress (EOS). If a soldering iron is not grounded properly, the voltage on the tip can reach as high as the AC linevoltage (i.e. AC 110V to 220V) due to capacitive coupling with power line cables. Studies* show that the current to the boardsfrom such contact can exceed several amperes damaging the components. Simply touching the board with tweezers when theoperator is not grounded can generate a damaging discharge. Monitoring of overvoltage on the circuit board itself can provideassurance that the alarm set voltage limit has not been exceeded.*"EOS from Soldering Irons Connected to Faulty 120VAC Receptacles"W. Farwell et. al., Raytheon Corporation. Presented at 2005 ESD SymposiumOrdering Information3M Iron Man and Iron Man Plus Monitors come with:• Monitor lead with alligator clip• Ground connection hardware (Iron Man Monitor only)• Power adapter• User's guidePlease contact factory for other options and accessoriesU.S. Patents 6,930,612; 7,118,380, other patents applied for.CTC-33X-YIron Man 0Iron Man Plus 1U.S. Power Adapter USUniversal Power Adapter WWAccessoriesDissipative Vinyl Three-Layer Table Mats 8200 SeriesDual Conductor Fabric Wrist Band 2368Dual Conductor Coiled Ground Cord, 10 ft. 2370Replacement Terminal Board with Jack CTA251
其它相关产品
相关搜索推荐
找不到合适信息?

留下您的采购意愿,我们将帮您推荐诚信供应商!
注:此功能仅对企业用户开放,如果您不是企业用户请点击注册.

免责说明
本网所展现的公司信息、产品信息及其他相关信息均由企业自行提供,信息的真实性、准确性和合法性由商铺所属企业完全负责。全球石油化工网对此不承担任何保证责任。
关于我们 | 会员服务 | 电子样本 | 邮件营销 | 网站地图 | 诚聘英才 | 意见反馈
Copyright @ 2012 CIPPE.NET Inc All Rights Reserved 全球石油化工网 版权所有
京ICP证120803号 京ICP备05086866号-8 京公网安备110105018350