导航:全球石油化工网 >> 产品频道 >> 工业自动化 >> 电线、电缆 >> 电力电缆
该公司还有3条同类“电力电缆”供应商机
详细信息
 产品认证:   聚氯乙烯  绝缘材料:   中、低压电力电缆(35千伏及以下)
 电压等级:   3  护套材质:   ISO9001-2000
 线芯材质:   裸铜线  芯数:   聚乙烯
 工作温度:   GB(mm) ((℃))  导体结构:   GB(mm) ((根数直径)(B/R))
 额定电压:   电力电缆 ((KV))  用途:   3*4(mm2)

聚氯乙烯绝缘电力电缆产品标准Standard本产品按GB12706《额定电压35KV及以下铜芯、铝芯塑料绝缘电力电缆》标准生产,同时还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。The product is manufactured according to the standard of GB12706 or IEC , BS , DIN and ICEA upon request适合范围Applications本产品适用于额定电压35KV及以下配电网或工业装置中固定敷设之用。The product is suitable for use in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 35KV.使用特性Operating characteristics1、 ● 额定电压3.6/6KV~26/35KV交联聚乙烯绝缘电力电缆XLPE Insulated Electrical Cable for rated power frequency voltage Uo/U:3.6/6KV~26/35KV.● 电缆导体的允许长期最高工作温度为90℃。Max.permissible continuous operating temperature of conductor:90℃● 短路时(最长持续时间不超过5s)电缆导体的最高温度不超过250℃。Max.short-circuit temperature of conductor shall not exceed 250℃.(5s Max. Duration)● 敷设电缆时环境温度应不低于0℃。The bending radius of single-core cable shall not less than 20 times of the cable diameterThe bending radius of three-cores cable shall not less than 15 times of the cable diameter2、 ● 额定电压0.6/1kv交联聚乙烯绝缘电力电缆XLPE Insulated Electrical Cable for rated power frequency voltage Uo/U : 0.6/1KV● 电缆导体的允许长期最高工作温度为90℃。Max.permissible continuous operating temperature of conductor : 90℃● 短路时(最长持续时间不超过5s)电缆导体的最高温度不超过250 ℃Max.short-circuit temperature of the conductor shall not exceed 250 ℃● 敷设电缆时环境温度应不低于0 ℃The ambient temperature under installation shall not below 0 ℃● 电缆弯曲半径不小于电缆外径15倍The bending radius of a cable shall not less than 15 times of the cable diameter .3、 ● 额定电压0.6/1KV聚氯乙烯绝缘电力电缆。PVC Insulated Electrical Cable for rated power frequency voltage Uo/U : 0.6/1KV● 电缆导体的允许长期最高工作温度为70 ℃Max.permissible continuous operating temperature of conductor : 70 ℃● 短路时(最长持续时间不超过5s)电缆导体最高温度不超过:160℃Max.short-circuit temperature of the conductor shall not exceed :160℃● 敷设电缆时环境温度应不低于0 ℃The ambient temperature under installation shall not below 0 ℃● 电缆弯曲半径不小于电缆外径10倍The bending radius of a cable shall not be less than 10 times of the cable diameter.电缆额定电压的选择Voltage designation● 电缆的额定电压应适合于电缆使用系统的运行状况,用Uo/U(Um)kv表示。Uo—电缆设计用的导体与屏蔽或金属套之间的额定工频电压;U—电缆设计用的导体之间的额定工频电压;Um—设备可承受的“最高系统电压”的最大值。The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used , and is expressed in the form Uo/U(Um)kv .Where:Uo—The rated power-frequency voltage between conductor and screen or metallic-sheath , for which the cable designed;U — The rated power –frequency voltage between conductors , for which the cable designed ;Um—The maximum value of the “highest system voltage “ for which the equipment may be operated注:第一类——用于单相接地故障时间每一次一般不大于1min, 亦可用于最长不超过8h , 第年累计不超过125h 的系统。第二类一一用于接地故障时间更长的系统及对电缆绝缘性能要求较高的场合。
其它相关产品
相关搜索推荐
找不到合适信息?

留下您的采购意愿,我们将帮您推荐诚信供应商!
注:此功能仅对企业用户开放,如果您不是企业用户请点击注册.

免责说明
本网所展现的公司信息、产品信息及其他相关信息均由企业自行提供,信息的真实性、准确性和合法性由商铺所属企业完全负责。全球石油化工网对此不承担任何保证责任。
关于我们 | 会员服务 | 电子样本 | 邮件营销 | 网站地图 | 诚聘英才 | 意见反馈
Copyright @ 2012 CIPPE.NET Inc All Rights Reserved 全球石油化工网 版权所有
京ICP证120803号 京ICP备05086866号-8 京公网安备110105018350